Tel : 0086-0371-86172891
Grade | Thickness (mm) | Density (kg/dm3) | Maximum iron loss P15/50 (W/kg) | Minimum magnetic induction B50 (T) | Minimum lamination coefficient (%) |
B50A800 | 0.50 | 7.80 | 8.00 | 1.70 | 96.0 |
Grade | Thickness (mm) | Density (kg/dm3) | Maximum iron loss P15/50 (W/kg) | Minimum magnetic induction B50 (T) | ||||||
P10/50 | P15/50 | P10/60 | P15/60 | B10 | B25 | B50 | B100 | |||
B50A800 | 0.50 | 7.80 | 2.67 | 5.70 | 3.34 | 7.11 | 1.57 | 1.66 | 1.74 | 1.84 |
BaoSteel | NSC | JFE | TKS | POSCO | NI&SCo | AK |
B50A800 | 50H800 | 50JN800 | M800-50A | 50PN890 | 2011 | - |